文章摘要
直流偏磁对输电线路距离保护的影响分析
Influence of DC Magnetic bias on distance protection of transmission line
Received:December 29, 2013  Revised:January 05, 2014
DOI:
中文关键词: 直流偏磁  距离保护  测量阻抗  直流偏移系数  动作特性
英文关键词: DC magnetic bias  distance protection  measured impedance  DC coefficient operating characteristic
基金项目:国家自然科学基金(51377016)
Author NameAffiliationE-mail
WANG Zhen-hao School of Electrical Engineering,Northeast Dianli University zhenhaowang@126.com 
WANG Xue-bin* School of Electrical Engineering,Northeast Dianli University wxb368@126.com 
SONG Li Gansu province Baiyin Power Supply Company  
TONG Xin Liaoning Province Shenyang Power Supply Company  
Hits: 1739
Download times: 1215
中文摘要:
      高压直流输电运行于单极大地回路方式时,太阳耀斑活动产生的地磁感应电流会使变压器或保护用电流互感器产生直流偏磁现象。当直流偏磁电流进入交流系统后,阻抗继电器的测量阻抗中会产生一个附加阻抗,使阻抗继电器的测量阻抗变大,从而导致距离保护出现欠范围拒动作。本文建立了相应的输电线路距离保护系统模型,推导出了直流偏磁条件下阻抗继电器测量阻抗表达式,同时为了直观的衡量直流偏磁电流对测量阻抗的影响,定义出了直流偏移系数,通过分析不同直流偏移系数条件下的距离保护动作特性,并利用PSCAD/EMTDC仿真软件在不同直流偏移系数条件下进行仿真分析,验证了理论分析的正确性。
英文摘要:
      When High-voltage direct current (HVDC) project operates in monopolar mode or the ground induced current (GIC) produced by solar flare activity, which would cause DC magnetic bias phenomena of transformer or current transformer for protection. While the direct current flow into the power system, an additional impendence would have shown in measured impedance of the impedance relay, which can expand the measured impedance, this will make the impedance relay under-reaching operating. A corresponding analysis system model of distance protection for transmission lines is established in this paper. The expression of measured impedance of the distance relay is derived when considering the DC magnetic bias, meanwhile, in order to intuitionistic weigh the influence of the distance relay caused by DC migration bias, a concept of DC magnetic coefficient is put forward. Through analyzing the operating characteristics of distance protection in different DC coefficient and simulating by using PSCAD/EMTDC simulation software and results are used to verify the validity of the theoretical analysis.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd