• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
关口电能计量故障监测报警装置及主站研究
A Research on the Alarming instrument and Master Station of the Gateway Energy Measuring Failure
Received:December 31, 2013  Revised:January 02, 2014
DOI:
中文关键词: 关口计量故障  102通信规约  多元电量追补
英文关键词: failure  monitoring of  gateway energy  measurement, 102 Communication  Protocol, multi-electricity  compensation
基金项目:
Author NameAffiliationE-mail
YANG Shuai* Measuring Center of Hunan Electric Power CORP yang_shuai@126.com 
CHEN Xiang-qun Measuring Center of Hunan Electric Power CORP  
ZHAO Dan Measuring Center of Hunan Electric Power CORP  
XU Zheng State Grid Shandong Electric Power CORP  
XIE Xiao-qian State Grid Hunan Electric Power CORP  
GUO Ding-ying Measuring Center of Hunan Electric Power CORP  
YANG Fang Measuring Center of Hunan Electric Power CORP  
ZHANG Can-hui Measuring Center of Hunan Electric Power CORP  
Hits: 2417
Download times: 786
中文摘要:
      本文针对近年来频发的省级关口计量故障,研究了一套计量故障事件监测及报警系统,并给出了具体的软硬件实现。该系统通过扩展102通信规约,利用故障监测终端实时采集关口电能表失压、失流、断相以及不对称功率等事件,通过PSTN或LAN传输至主站与EMS/SCADA、用电信息采集系统进行故障核实,并采用SMS短信、IMAP邮件、页面警示方式提醒运维人员进行及时处理。此外,本文还介绍了一种多元电量追补技术,根据不同的故障方式,自动生成电量追补公式,通过母线电量、变压器三侧电量、线路对侧电量等多种平衡措施对追补电量进行验证和追补。
英文摘要:
      As recurrent failures in gateway measurement over recent years, this thesis researches on the measurement monitoring and alarming of a system with specific and viable software and hardware. By extending the 102 Communication Protocol of Central China, this system makes use of the failure monitoring terminal to real time collect the events such as voltage lose, current lose, TV failure and power imbalance, transmits them to the master station through PSTN or LAN, and make use of EMS/SCADA and the electrical energy acquistion system to verify the failures. Then by means of SMA massage, IMAP mail and online warning, the system reminds the OAM staff to process in time. Further more, a way of multi-electricity compensation is introduced. Electricity compensation formula is automatically generated according to different failure, and the compensated electricity will be verified and compensated by the balance measures such as the electricity of the busbar, the 3 sides electricity of the main transformer and the electricity of the opposite wires.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd