文章摘要
矿用本安型消弧补偿装置的研究
Research on Mine Intrinsic Safe Arc Elimination and Suppression Device
Received:February 13, 2014  Revised:February 22, 2014
DOI:
中文关键词: 矿用  谐振接地  本安型  调容式消弧线圈  电流补偿
英文关键词: Mine  Resonance grounding  Intrinsic safe type  Arc Suppression Coil with Switched Capacitors  Current Compensation
基金项目:
Author NameAffiliationE-mail
Liu Yi* Xi''an Research Institute of China Coal Technology & Engineering Group Corp gf_233@163.com 
fuzhouxing School of Electrical and Control Engineering,Xi’an University of Science and Technology  
zhangpeng School of Electrical and Control Engineering,Xi’an University of Science and Technology  
zhaopengpeng School of Electrical and Control Engineering,Xi’an University of Science and Technology  
Hits: 1402
Download times: 632
中文摘要:
      运用自制的矿用本安型防爆消弧补偿设备,进行了10kV煤矿电网谐振接地系统在发生单相接地故障过程中的影响研究,结合对调容式消弧线圈和相关矿用自动化设备的研究,通过仿真验证证明,分析了矿用自动消弧补偿装置在消弧调谐方面的作用。设计了装置的软硬件,实验结果表明,在10kV煤矿电网发生单相接地后产生59.016A的接地电流,而经过检测后补偿设备产生62.885A的补偿电流,最终使故障残流减小为3.869A,在电网安全范围内成功实现灭弧功能并使其不再复燃。
英文摘要:
      Application ofSmine intrinsically safeSexplosion-proofShomemade compensation arc suppressionSdevice,StheS10kV resonanceSgrounding system in coal mine power networkSsingle-phase grounding faultSeffect during the study,Scombined withStheSstudy ofScapacitiveSarc suppression coilSand relatedSminingSautomation equipment,SprovenSby simulation,Sanalysis ofSautomaticSarc-suppressionSdeviceSin theSfireSarc tuningSfunction.SSoftware and hardwareSdeviceSwas designed,Sthe experimental results show that,StheS59.016ASgroundingScurrent in 10kVScoal mine power networkSsingle-phase grounding,Sthe compensation currentSandStestedSafterScompensation equipmentSto produce 62.885A,StheSfault residualSflowSis reduced to 3.869A,Sin the power gridSsafety rangeSis successfullySarcSfunctionSand make itSno longer.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd