• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于改进双端法的输电线路行波故障定位
Traveling waves fault location of transmission lines based on improved double terminal method
Received:February 18, 2014  Revised:February 18, 2014
DOI:
中文关键词: 输电线路  行波波速  三测点定位系统  小波变换
英文关键词: transmission line, traveling wave speed, three measurements locating system, wavelet transform
基金项目:国家自然科学基金资助(60974125)
Author NameAffiliationE-mail
gaoyanfeng* North China Electric Power University Hebei University of Engineering gaoyanfeng01@126.com 
zhuyongli North China Electric Power University  
Hits: 1758
Download times: 1093
中文摘要:
      行波波速的不确定往往给行波故障定位带来较大误差。为了克服行波波速对输电线路故障行波定位的影响,提出了一种利用同一条线路的三个测量点进行故障定位的方法。在双端行波故障定位原理的基础上,构造了一个三测点的定位系统,推导出不计及行波波速的故障定位新算法。该方法利用小波变换确定故障初始行波到达三个测量点的时间即可实现故障定位,与以往方法相比避免了因行波反射衰减无法测量而导致定位失败。PSCAD仿真结果表明,该方法定位精度高,且简单易行。
英文摘要:
      The uncertainty of traveling wave speed always causes deviation to the fault location. In order to restrain the influence of traveling wave speed on transmission line fault location, a new method of fault location by using three measurements on the same line was presented in this paper. Based on the principle of double terminal traveling wave fault location, a locating system with three measurements was constructed, and a new locating algorithm without influence of wave speed was derived. It needs the time of the fault initial traveling wave arriving at three measurements to realize fault location, the time can be measured by wavelet transform, compared with the previous methods, it avoid the locating failure that caused by the attenuation of the reflecting wave. The simulation results of PSCAD show that the proposed method has high accuracy in location, and it is easy to implement.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd