文章摘要
基于免疫算法的高容错性广域保护研究
Wide-area Protection Based on the Improved Immune Algorithm with Fault-tolerance
Received:March 05, 2014  Revised:March 06, 2014
DOI:
中文关键词: 区域保护,后备保护,改进免疫算法,容错性
英文关键词: regional  protection, backup  protection, the  improved immune  algorithm, fault  tolerance capability
基金项目:
Author NameAffiliationE-mail
GU Xin* School of Electrical Engineering and Information,Sichuan University 418425689@qq.com 
LV Feipeng School of Electrical Engineering and Information,Sichuan University  
wushangshang Sichuan Zigong Electric Pow er Bureau, Zigong 643000, China  
LIU Lingling School of Electrical Engineering and Information,Sichuan University  
WANG Congwei School of Electrical Engineering and Information,Sichuan University  
Hits: 2053
Download times: 1344
中文摘要:
      通过对广域保护应用基础的研究,本文提出利用区域保护电网信息,将区域电网结构与改进免疫算法有机结合起来,使该区域后备保护能达到更高效,信息容错性更高,判断更准确的效应。基于此,本文选择了合适的区域保护结构,使用改进免疫算法建立了故障数学模型,并验证了模型的有效性和高容错性。
英文摘要:
      Based on wide-area protection applied basic research, the paper puts forward using regional protection grid information to combine regional power grid structure and improved immune algorithm organically. This research has more efficient regional backup protection, higher information fault tolerance and more accurate malfunction judgment, etc. This paper chooses the appropriate regional protection structure, and use improved immune algorithm to establish the fault mathematic model, finally verify the validity of the model and high fault tolerance.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd