文章摘要
基于10kV配电网的电压暂降源的定位与识别
Location and Recognition of Voltage Sag Source Based on 10kV Distribution System
Received:March 07, 2014  Revised:March 07, 2014
DOI:
中文关键词: 配电网  电压暂降源  定位  识别
英文关键词: distribution  system, voltage  sag source, location, recognition
基金项目:
Author NameAffiliationE-mail
YANG Hao* North China Electric Power University xuehao_yang@foxmail.com 
LI Yong-gang North China Electric Power University  
LI Jian-wen North China Electric Power University  
Li Zhongliang State Grid Corporation of Jiaozuo,Henan  
Hits: 1664
Download times: 827
中文摘要:
      提出了一种基于10kV配电网的电压暂降源定位与识别的方法。利用有限的监测点采集的数据,根据电压暂降发生时系统中能量的流动变化,判定电压暂降源相对于监测点的位置;从三相电压是否平衡、暂降深度、有功功率变化和电压总谐波畸变率等方面研究了几种常见电压暂降源的特征;根据各类电压暂降源的特性以及仿真试验提取相应的特征量并设立判据,从而实现了对线路故障、感应电机启动和变压器投运引起的电压暂降的识别。
英文摘要:
      Based on a 10kV distribution system, a new voltage sag source location and recognition method is brought forward. With limited data, determine the voltage sag location according to the flow of the energy in the system. Make an analysis on characteristics of several common voltage sag source from the balanced of three-phase voltage, sag depth, changes of active power and Total Harmonic Distortion of voltage. According to the characteristics of the source and simulation, the criterion has been established. Then achieve the location and recognition of the voltage sag source caused by power system short-circuit faults, start up of induction motors and energization of power transformers.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd