文章摘要
一种基于频率整合法的配电网单相接地故障测距技术
A new fault location method based on frequency integration in distribution network
Received:March 09, 2014  Revised:March 09, 2014
DOI:
中文关键词: 中低压配电网  单相接地故障  故障测距  频率整合  prony
英文关键词: medium voltage distribution network  single-phase ground fault  fault location  frequency integration  prony
基金项目:
Author NameAffiliationE-mail
Pang Le-le* College of Information and Electrical Engineering,China University of Mining and Technology,Xuzhou,221008 15862144908@163.com 
LI Peng-fei China  
Hits: 1616
Download times: 686
中文摘要:
      我国中压配电网绝大多数采用中性点非有效接地运行方式,故障类型以单相接地为主。本文首先对配网的单相接地故障过程进行了详细分析,理论上分析了基于故障暂态信号频率进行故障测距的可行性。为了提高测距的可靠性和灵敏性,本文利用prony算法对故障暂态零序电流信号进行了提取整合,提出了基于频率整合法的单端故障测距方法。最后通过PSCAD/EMTDC软件搭建了仿真线路模型,利用MATLAB进行数据分析和算法仿真,结果验证了本文的测距方法具有较理想的测距效果。
英文摘要:
      The majority of medium voltage distribution network is working on non-effectively grounded mode, and most of its fault type is single-phase ground fault. This thesis firstly analyzed the Single-phase ground fault process in detail, theoretically analyzed the feasibility of fault location based on signal frequency. To improve the reliability and sensitivity of this method, we use prony algorithm to extract the fault transient zero-sequence current signal and integrated, and proposed the fault location method based on frequency intergration. Finally we take simulations by PSCAD/EMTDC and MATLAB, verified accuracy and validity of procedures proposed above.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd