• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
紫外放电检测量化表征及预测方法研究
Characterization and prediction methods study to quantify UV discharge detection
Received:March 10, 2014  Revised:November 11, 2014
DOI:
中文关键词: 紫外检测  信息量化  放电强度  状态预测
英文关键词: UV  detection,Information  quantify,Intensity  Discharge,State  prediction
基金项目:国家自然科学基金 (61205076);
Author NameAffiliationE-mail
MA Li-xin University of Shanghai for Science Technology malx_aii@sina.com 
Zhang Jun* University of Shanghai for Science Technology 1016203452@qq.com 
Hits: 2374
Download times: 895
中文摘要:
      随着智能电网的建设和电压等级的提高,局部放电已经成为输变电设备,特别是高压电气设备上绝缘介质老化的重要原因,因而局部放电的检测和量化评估也就成为绝缘介质状况监测研究的关键。本论文构筑一套新型的紫外放电监测系统,提出用设备放电的物理量来表征放电的状态,以光子数来量化放电强度,进而定量评估设备绝缘性能和预测设备寿命。有效解决了对早期放电难以定量计测,无判断设备更新标准的难题。通过计算仿真以及集成系统的测试,该系统能实时地监控高压电器放电并且判断放电强度,验证了该方法的可行性和有效性。对局部放电紫外检测领域的研究具有一定的理论意义,对电力系统安全运行及实现输变电设备在线监测提供了有效的解决方案,为紫外检测标准的建立打下了基础。
英文摘要:
      With the smart grid construction and improvement of voltage levels, partial discharge has become a power transmission equipment particularly important reason for the high-voltage electrical equipment dielectric aging, thus partial discharge detection and quantitative assessment of the insulation monitoring studies media has become a key condition. In this paper, to build a new UV Discharge Monitoring System, discharge equipment proposed to characterize the physical state of the discharge, in order to quantify the number of photons intensity discharge, further quantitative assessment and prediction of equipment insulation equipment life. Effective solution for early discharge is difficult to quantify measurement, no judgment standard equipment upgrades puzzle. Calculated by simulation and testing of integrated systems, the system can monitor the real-time voltage electrical discharge and determine the intensity discharge, the feasibility and effectiveness of this method. Research in the field of partial discharge UV detector has a certain theoretical significance, for the safe operation of power systems and power transmission equipment to achieve online monitoring provides an effective solution, UV detection criteria for the establishment of a foundation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd