• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电力系统暂态稳定风险量化分级方法研究
Research on The Quantitation and Classification Method of Power System Transient Stability Risk
Received:March 25, 2014  Revised:March 25, 2014
DOI:
中文关键词: 电力系统  暂态稳定  风险评估  量化分级  ALARP原则
英文关键词: power system  transient stability  risk assessment  quantitation and classification  ALARP principle
基金项目:
Author NameAffiliationE-mail
Zhang Zhonghui Nanchang University 249977758@qq.com 
Wan Dong* Nanchang University 249977758@qq.com 
Hits: 2080
Download times: 853
中文摘要:
      提出了基于风险理论的暂态稳定风险评估量化分级方法。从风险理论的角度出发,综合考虑运行方式、故障发生、故障类型、故障地点和重合闸等不确定因素计算系统失稳的概率,以暂态失稳导致的切负荷百分比作为后果,定量的得出暂态稳定风险值,并依据《国家电网公司安全事故调查规程》应用ALARP原则对风险量化分级,使风险值的意义更加清晰明确,为运行人员提供一定参考依据。最后,以WSCC3机9节点为例,说明了该方法的可行性和有效性。
英文摘要:
      This paper presents a method about quantitation and classification of transient stability risk assessment based on the risk theory. From the point of risk theory, Uncertain factors include the operation, the fault occurring, the fault type, the fault location and the automatic reclosing process and so on, the consequence is the percentage of load cutting caused by transient instability, and then the risk value of transient stability is derived which is quantitative, then use the ALARP principle based on "safety accident investigation procedures of State Grid " to quantify and classify the risk value, which can make the meaning of risk value more clear, and also provide a reference for operating personnel. Finally, the WSCC 3 unit 9 bus test system is used to illustrate the feasibility and effectiveness of this method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd