• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于本体和云模型的电能质量信息状态监测平台
Information Condition Monitoring Platform of Power Quality Based onOntology and Cloud Mode
Received:April 01, 2014  Revised:April 01, 2014
DOI:
中文关键词: 本体  云模型  电能质量  状态监测
英文关键词: ontology  cloud mode  power quality  condition monitoring  
基金项目:
Author NameAffiliationE-mail
LIU Xiao-hua Foshan Electric Power Bureau sushaoze@126.com 
HUANG Jing Foshan Electric Power Bureau  
SU Shaoze* School of Electrical and Information, Sichuan University 513853116@qq.com 
Hits: 2302
Download times: 931
中文摘要:
      提出了一种基于本体技术和云模型的电能质量信息状态监测平台的搭建方法。首先计算每天监测数据的统计特征值,构建电能质量信息状态监测检索本体;然后根据各种检索条件组合关系在检索本体的指导下检索出每天样本的均值和方差,从而计算出总体样本的均值和方差,并根据总体样本建立电能质量各项指标的云模型;最后采用云模型的统计规律来判断电能质量信息状态监测的结果,实现了电能质量信息状态诊断和实时监测的功能。详细介绍了电能质量状态信息检索本体建立的关键步骤、电能质量指标云模型建立方法、利用云模型判断电能质量信息状态的方法。实例分析表明了该平台的有效性,具有一定工程实用价值。
英文摘要:
      A construction method based on ontology technology and cloud mode for an information condition monitoring platform of power quality is proposed. Firstly, the statistical characteristic value of daily monitoring data is calculated, the information condition monitoring retrieval ontology of power quality is set up. Then, the every-day sample mean and variance is retrieved in the guidance of retrieval ontology according to the different combination of the retrieval conditions, and in line with the total sample, the cloud mode of the indicators for power quality is established. Finally, adopting the statistical law of cloud mode to estimate the condition monitoring result of power quality realizes the function of information state diagnosis and real-time monitoring for power quality. The critical construction process of the information condition monitoring retrieval ontology of power quality, the establishment method for index cloud mode of power quality and the method to estimate the information state of power quality utilizing cloud mode are introduced in detail. The availability of this platform is indicated by instance analysis, which is of certain engineering practical value.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd