• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于DLPTP时钟同步机制的电力用电信息采集系统对时方法研究
Research based on the time clock synchronization mechanism DLPTP power information collection system
Received:April 02, 2014  Revised:April 02, 2014
DOI:
中文关键词: 电力用电信息采集  时钟同步  DLPTP协议  采集终端
英文关键词: Electric information acquisition, clock synchronization,DLPTP protocol, data acquisition terminal
基金项目:
Author NameAffiliationE-mail
XU Qing Jiangsu Electric Power Company Research Institute qing_xq@yahoo.com 
JI Feng Jiangsu Electric Power Company Research Institute  
BAO Jin* Jiangsu Electric Power Company Research Institute baj8403@163.com 
MU Xiao-xing Jiangsu Electric Power Company Research Institute  
TIAN Zheng-Qi Jiangsu Electric Power Company Research Institute  
ZHOU Chao Jiangsu Electric Power Company Research Institute  
Hits: 2247
Download times: 717
中文摘要:
      针对电力用电信息采集系统内主站、采集终端、电能表时钟的准确性问题,本文在电力系统传输规约的基础上自定义DLPTP协议,采用GPS首先对主站时间进行校准,然后以主站为基准,采用DLPTP协议对采集终端进行对时,最后调整电能表设备的时钟,逐步实现系统时钟的同步,从而保证了系统内所有设备时钟的一致性,有效提升了系统内采集数据的准确性。
英文摘要:
      The electric information acquisition system master station, data acquisition terminal, electric energy meter clock accuracy for power, this custom transmission protocol of power system based on DLPTP protocol, using GPS first calibrate the master of time, and then to the main station for reference, using DLPTP protocol by time of acquisition terminal, the final adjustment of electric energy meter the clock of the equipment, and gradually realize the synchronization of the system clock, so as to guarantee the consistency of all equipment clock system, effectively improve the accuracy of data acquisition system.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd