• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
一种改进的FBD指令电流检测方法研究
Improved Directive Current Detecting Method Based on FBD
Received:April 03, 2014  Revised:April 03, 2014
DOI:
中文关键词: 三相不对称系统  FBD法  瞬时对称分量  平均值理论
英文关键词: three-phase  asymmetry system,FBD  method,instantaneous  symmetrical components,current  mean value  theory
基金项目:
Author NameAffiliationE-mail
HUANG Zhi-chao Guilin University of Electronic Technology hzc8021@126.com 
SU Xiao-peng* Guilin University of Electronic Technology sxpengxf@126.com 
LI Jun Guangxi Power Grid Company Guilin Power Supply Bureau  
LIU Chao-pan Guilin University of Electronic Technology  
Hits: 1542
Download times: 506
中文摘要:
      在有源滤波器设计中,指令电流的检测是控制与补偿的关键技术环节。在三相电压不对称情况下,由于a相电压与其正序电压之间存在相位差,使传统FBD检测法在提取指令电流时存在误差,针对此不足提出一种改进的FBD检测法,该方法通过瞬时对称分量法检测电网电压基波正序分量的相位,减小了因三相电压不对称而导致的检测误差,同时引入电流平均值理论提取等效电导的直流分量,提高了指令电流检测的动态响应能力。仿真结果表明,基于改进FBD法的有源滤波器能够快速准确地检测和补偿三相不对称系统中的谐波和无功电流。
英文摘要:
      The detection of directive current is very important for APF. Because of the phase difference between a phase voltage and its positive sequence voltage in the three-phase asymmetry system, the directive current can not be detected accurately by traditional FBD method. An improved FBD detecting method was proposed, the improved FBD acquires the phase of the fundamental positive-sequence voltage by instantaneous symmetrical components, which reduces detection error caused by the three-phase voltage asymmetry, and introduces mean value theory to extract the linear part of equivalent conductance, so as to improve dynamic response capability of directive current detection. The simulation results verify that the APF based on the improved FBD can effectively detect and compensate harmonic and reactive current in the three-phase asymmetrical system.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd