文章摘要
对称和不对称故障下的并网光伏逆变器低电压穿越研究
Low Voltage Ride Through under Balance Fault and Unbalance fault for Grid-Connected PV Inverter
Received:April 07, 2014  Revised:April 07, 2014
DOI:
中文关键词: 光伏逆变器  低电压穿越  直接功率控制  正序负序电流  双闭环矢量控制
英文关键词: PV  inverter, low  voltage ride  through, direct  power control, positive  and negative  sequence current, double  closed-loop  vector control
基金项目:
Author NameAffiliationE-mail
HAN Xian-sui* State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University,School of Electronics and Electrical Engineering,Bei Jing 102206 han_xiansui@163.com 
LIU Qi-hui State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources( North China Electric Power University)  
Hits: 2777
Download times: 672
中文摘要:
      从改变控制策略上,成功实现电网故障下光伏逆变器的低电压穿越。分别提出了抑制对称故障的直接功率控制策略和抑制不对称故障的基于正序、负序电流的双闭环矢量控制策略。在对称故障时,采用限功率运行的方法改变输入功率指令,减少光伏电池对电网的输出功率,实现电网对称故障下的成功穿越。在不对称故障时,提取出电网中的正序和负序分量,采用正序和负序电流双闭环矢量控制,有效地抑制了瞬时电流冲击。仿真结果表明,两种不同故障工况下控制策略的合理性和有效性。
英文摘要:
      By means of the change of control strategy, successfully achieve the low voltage ride through of PV inverter under the grid fault. The direct power control strategy and double closed-loop vector control based on positive sequence, negative sequence current are respectively proposed under the balance fault and unbalance fault. When the voltage of grid is balanced, adopt the method of limiting active power to change the input power order, thus reduces the output active power of PV and realize LVRT successfully. When the unbalanced fault happens, carry out positive and negative sequence separation, positive and negative sequence current double-loop vector control are controlled. The simulation results show that the reasonable and effectiveness of the control strategy.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd