文章摘要
光伏电站低电压穿越技术研究
Research on Low Voltage Ride Through Technology for Grid-connected Photovoltaic Power Plant
Received:April 10, 2014  Revised:April 14, 2014
DOI:
中文关键词: 光伏电站  低电压穿越  协调控制  单相跌落故障
英文关键词: photovoltaic power plant, low voltage ride through, coordinated control, single-phase failure
基金项目:“本科教学工程”国家级大学生创新创业训练计划(201310290067)
Author NameAffiliationE-mail
SHI Xiang-qian* China University of Mining and Technology,School of Information and Electrical Engineering airshi2008@126.com 
GENG Yi-wen China University of Mining and Technology,School of Information and Electrical Engineering  
HUANG Zun-chen China University of Mining and Technology, SUN Yue-qi Honors College  
QU Zi-sen China University of Mining and Technology, SUN Yue-qi Honors College  
Hits: 3114
Download times: 689
中文摘要:
      针对大规模光伏电站在电网故障或扰动时突然脱网造成的严重后果,提出了一种光伏电站低电压穿越(Low Voltage Ride Through, LVRT)控制策略,详细分析了光伏并网逆变器控制策略以及LVRT有功电流和无功电流协调控制的实现方法。以单相跌落故障为例,进行了仿真和实验研究,结果表明所提出的控制策略不仅能保证并网逆变器在电压跌落期间输出不过流,而且能够向电网发出一定的无功功率以支撑并网点电压的恢复,实现低电压穿越。
英文摘要:
      According to the serious consequences caused by large-scale photovoltaic power plant off the grid when grid failure or disturbance taking place, a control strategy based on low voltage ride through of photovoltaic power plant is proposed. The control strategy of photovoltaic grid-connected inverter and the implementation of coordinated control of active and reactive current are analysed detailedly. Then the simulation and experiment are carried out for the single-phase failure. The results verify that the proposed control strategy can ensure the grid-connected inverter output current flow doesn't overcurrent during low voltage. At the same time, a certain amount of reactive power can be sent to the grid to support the recovery of grid voltage, so as to realize the capability of low voltage ride through.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd