基于HHT小电流接地电力电缆在线故障测距方法
A Method of Power Cable Fault Location Online in Neutral Point Ineffectively Grounded Power System Based on HHT
Received:April 16, 2014  Revised:April 16, 2014
DOI:
中文关键词: HHT  小电流接地系统  电力电缆  在线故障测距
英文关键词: HHT  Neutral point ineffectively grounded power system  Power cable  Fault location online
基金项目:
Author NameAffiliationE-mail
WANG Jian-yuan Northeast Dianli University free1971@163.com 
JU Mo-xin* Northeast Dianli University jumoxin@163.com 
JU Mo-ran Jilin University  
XU Zhi-xuan Northeast Dianli University  
MA Xue-ke Northeast Dianli University  
Hits: 1987
Download times: 744
中文摘要:
      使用电力电缆进行电力传输已经逐渐被推广,在小电流接地系统发生单相接地故障时,由于系统仍可运行1-2小时,这就要求在不断电的情况下,检测出故障的位置。本文提出一种基于HHT小电流接地系统电力电缆单端在线故障测距的方法,在电缆参数未知的情况下,采用合闸时产生的操作过电压行波在线测量行波波速,单相接地故障发生后,利用HHT寻找行波瞬时频率突变的时刻,并运用单端测距法实现电力电缆故障测距。最后,对算例进行数值仿真,仿真结果验证了该方法的可行性和实用性。
英文摘要:
      Power cable for power transmission has been gradually extended. The system can be still running 1-2 hours when single-phase-to-earth fault occurs, which requires the location of the fault is detected in the case of UPS. A method of power cable fault location online in neutral point ineffectively grounded power system based on HHT is proposed in this paper. Under the condition that the parameters of cable are unknown, the velocity of traveling wave in cable can be measured by the use of switching overvoltage wave which is generated when the closing occurs. When single-phase-to-earth fault happens, HHT is used to find the mutations moments of instantaneous frequency. Then the location of power cable fault is determined by one-terminal fault location method. Finally, the digital simulation results of an example show the effectiveness and practicability of this method.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd