• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
改进PR控制在直驱风机变流器中的应用
The Application of Improved PR Controller in Converter System of DD-PMSG
Received:April 18, 2014  Revised:June 05, 2014
DOI:
中文关键词: PI控制  鲁棒性  动态响应  PR控制
英文关键词: PI  controller, robustness, dynamic  response, PR  controller.
基金项目:
Author NameAffiliationE-mail
HUA Dong* College of Electrical Engineering,Xinjiang University 326827368@qq.com 
LI Yongdong College of Electrical Engineering,Xinjiang University  
CHENG zhijiang College of Electrical Engineering,Xinjiang University  
XIE Yongliu College of Electrical Engineering,Xinjiang University  
Fan Xiaochao College of Electrical Engineering,Xinjiang University  
Hits: 2032
Download times: 735
中文摘要:
      直驱永磁风力发电机的变流器通常采用基于PI矢量控制。传统的PI控制需要进行复杂的坐标变换,引入交叉耦合项和前馈补偿项,会影响系统的鲁棒性和动态响应效果。针对此类问题,本文提出一种改进的PR控制器,将其应用于直驱永磁风力发电机的变流器。分析其原理,并在PSCAD中建立系统仿真模型,验证改进的PR控制器的优势,证明该控制策略应用在直驱永磁风力发电机变流器中的有效性。
英文摘要:
      Generally, the converter system of direct-drive permanent magnet wind turbine uses vector control strategy which based on PI controller. The traditional PI controller needs complex coordinate transformation, and adds the cross-coupling terms and compensation terms of feed-forward,all this will affect the robustness and the dynamic response performance of the system. To solve such problems, this paper presents an improved PR controller, and applies it to the direct-drive permanent magnet wind turbine converter system. Through analyzing the principles, and establishes the simulation model in PSCAD, verified the improved PR controller"s advantages, proved the effectiveness of the application of improved PR controller in the converter system of direct-drive permanent magnet wind turbine.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd