基于EMS数据的电容式电压互感器在线监测系统研究
The research on on-line monitoring system of capacitor voltage transformer based on EMS data
Received:April 22, 2014  Revised:April 22, 2014
DOI:
中文关键词: 电容式电压互感器,二次电压,EMS数据,在线监测系统
英文关键词: capacitor voltage transformer, secondary voltage,EMS data,on-line monitoring system.
基金项目:
Author NameAffiliationE-mail
linhao* China Electric Power Reserch Institute linhao@epri.sgcc.com.cn 
Hits: 2310
Download times: 912
中文摘要:
      随着电容式电压互感器(CVT)在电力系统中的广泛使用,运行中也出现了一些问题,其中较常见的是内部电容元件的击穿故障,目前多数CVT在线监测系统需增加一次硬件设备,这不仅增加了系统投入,更可能影响系统的可靠性,本文利用广东电网中运行成熟的EMS(能量管理系统)中的CVT二次电压数据,研究二次电压变化与CVT自身状态的关系,通过理论计算与统计分析相结合确定了故障判断阈值,在不增加一次系统的硬件投入的基础上,建立了实时监测CVT运行状态的故障分析系统,避免了CVT故障的发展、威胁系统的安全,从而达到提高电力系统运行可靠性的目的。
英文摘要:
      With the widespread use of capacitor voltage transformer(CVT) in power system, there exist a few problems, among which internal capacitance component breakdown failure is one of common problems.Now a large amount of CVT on-line monitoring system need to add primary hardware equipment,which not only would increase investment,but also might affect system security.This article use CVT secondary voltage in EMS(energy management system)that has been in steady operation in Guangdong power grid corporation, and research on the relation between CVT self-state and secondary voltage, then determine threshold of fault diagnosis through combination of theoretic calculation and statistical analysis, in the end has established CVT on-line monitoring system without addition of primary system hardware equipment,this system could prevent fault deterioration and threaten safety of system, so as to achieve the goal of increasing power system stability.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd