• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于MCR的风电场动态无功补偿控制策略
The Control Strategy of the Dynamic Reactive power compensationin Wind Farm with MCR
Received:May 02, 2014  Revised:May 02, 2014
DOI:
中文关键词: 风电场  无功补偿  控制策略  电压稳定
英文关键词: wind farm  reactive power compensation  control strategy  voltage stability
基金项目:
Author NameAffiliationE-mail
WANG Jin-hao State Grid Shanxi Electric Power Research Institute yangyue29@aliyun.com 
Wang Kang-ning State Grid Shanxi Electric Power Research Institute  
XU Long State Grid Shanxi Electric Power Research Institute  
LEI Da State Grid Shanxi Electric Power Research Institute  
YANG Yue* North China Electric Power University,Changping District yangyue29@aliyun.com 
Hits: 1637
Download times: 751
中文摘要:
      近年来风电场数量及装机容量快速增长,风电接入系统给电网带来了越来越显著的影响。无功补偿作为改善风电场电能质量,提高系统运行稳定的重要措施,在风电场得到了广泛的应用。本文提出了一种基于风电场动态无功补偿装置的无功电压控制策略。通过测量并网点电压,充分利用MCR的连续调节特性,与FC投切相配合,满足风电场系统的无功电压需求。最后结合某含有MCR的实际风场进行了仿真分析,验证了所提出的策略正确性。
英文摘要:
      In recent years, the number of wind farms and its installed capacity grows rapidly. Wind power has more and more impact on power grid. As an important measure to improve the power quality and the stability of the system operation, reactive power compensation has been widely used in the wind farm. In this paper, a reactive power and voltage control strategy of dynamic reactive power compensation in wind farm was proposed. By measuring the input voltage of wind farm, making full use of continuous regulation characteristics of MCR and coordinating of switching FC to meet the voltage and reactive power demand in wind farm. Finally, taking an actual wind farm with MCR for simulation analysis, the validity of proposed strategy was verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd