文章摘要
一种基于暂态电流的故障测距方法
A Fault Location Method Based on Transient Current
Received:June 11, 2014  Revised:April 27, 2015
DOI:
中文关键词: 故障测距  电压凹陷  电力系统
英文关键词: fault  location, voltage  dip, power  system
基金项目:
Author NameAffiliationE-mail
CHENGZHIYOU Power Quality Engineering Research Center, Ministry of Education
School of Electronics and Information Engineering, Anhui University 
136372186@qq.com 
GEXIN* School of Electronics and Information Engineering, Anhui University 136372186@qq.com 
Hits: 1607
Download times: 536
中文摘要:
      输电线路故障的准确测距对于维持电力系统稳定起到了非常重要的作用。本文以R-L输电线路模型为基础,提出了一种基于暂态电流信号的三相故障测距定位方法。该方法首先对发生电压凹陷时间内的三相电流信号滤除基频分量,再对处理后的电流信号进行绝对值修正,接着对该信号进行对数变换;最后根据对数变换后的数据求出斜率,再由斜率定位发生故障线缆距离。该方法计算量小,仿真实验表明定位故障距离精确度较高,具有应用及推广的前景。
英文摘要:
      It is played a very important role for the power system stability to detect the transmission line fault location accurately. Through using transient current signal, this paper presents a transmission line fault location detection method for the three-phase fault which based on the R-L transmission line model. In the method, filter out the fundamental frequency component of the current signal when the voltage dips firstly. Secondly, change the processed current signal into absolute value. Then, dispose the current signal through logarithmic transformation. Finally, after the logarithmic transformation, get the slope by mean of the data. According to the slope, transmission line fault location could be detected. Simulation results show that the method can easily and efficiently detect transmission line fault location. The method has the prospect of application and promotion.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd