• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于戴维南等值的电压稳定评估方法
Voltage Stability Assessment Approach Based on Thevenin Equivalent
Received:June 21, 2014  Revised:July 20, 2015
DOI:
中文关键词: 戴维南等值  遗忘因子  递推最小二乘  抗差估计
英文关键词: Thevenin equivalent, forgetting factor, recursive least squares, robust estimation
基金项目:
Author NameAffiliationE-mail
ZHANG Yan* Hefei Power Supply Company zhy2358@126.com 
Yang Zhen Changji Electric Power Bureau  
XIE Hua-zhi Changji Electric Power Bureau  
HE Cheng-ming Changji Electric Power Bureau  
DENG Xiang-yang Changji Electric Power Bureau  
FAN Xin-qiao NARI Group Corporation 627809182@qq.com 
HanYu NARI Group Corporation  
LIU Bing Changji Electric Power Bureau  
Hits: 2214
Download times: 873
中文摘要:
      从等值模型和参数辨识方法两方面分析了戴维南等值方法在电压稳定分析中的问题。首先从系统节点电压方程出发,验证基于极限点处戴维南等值阻抗与负荷阻抗相等这一性质构造的稳定裕度指标具有较好的实用性,而此方法的关键在于系统各时刻等值参数的跟踪。其次比较了现有参数跟踪算法,分析了含遗忘因子最小二乘递推算法应用于此时出现数值稳定性问题的根本原因,根据估计误差提出了改进算法。最后分别以2节点系统和10节点系统两个仿真算例验证了该算法的有效性。
英文摘要:
      Equivalent model and parameter identification are both analysed in voltage stability analysis based on Thevenin equivalent. This paper demonstrates that Thevenin equivalent impedance is equal to load impedance at stability limiting point. Stability index based on this character provides higher practicability, while the key point is equivalent parameter tracking. Existing parameter tracking methods are compared in this paper and essence of numerical stability in recursive least squares method. A modified method considering estimation error and variable forgetting factor is proposed. Numerical simulations were conducted on 2-bus system and 10-bus system to demonstrate the effectiveness of this criterion.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd