文章摘要
移动基站和变电站共建时电气防护间距分析
Analysis of Electrical Protection Distance in Substation and Mobile Base Station Co-construction
Received:June 27, 2014  Revised:June 30, 2014
DOI:
中文关键词: 防护间距  变电站  移动基站  接地网  雷击  骚扰电压
英文关键词: protection  distance, substation, mobile  base station, grounding  grid, lightning, disturbance  voltage
基金项目:
Author NameAffiliationE-mail
Li Hui-qi Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University,Baoding,Hebei,071003 huiqili@263.com 
Diao Shou-ren* Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University,Baoding,Hebei,071003 136044539@qq.com 
ZHANG Jian-chen State Grid Hebei Information  
GAO Zhi-xin State Grid Hebei Information  
LI Xiao-long State Grid Hebei Electric Power Company  
Hits: 1425
Download times: 556
中文摘要:
      移动基站和变电站共建时必须要考虑的是安全的电气防护间距。本文从雷击基站时对变电站二次电缆骚扰电压的影响,变电站开关操作、短路故障对基站接地网的影响三方面进行分析。根据相关国内外标准计算变电站基地网和移动基站接地网不同连接方式、不同间距时的电气参数,得出安全的电气防护间距。本文结论可为工程建设提供理论依据,具有较高的实际参考价值。同时对于开展电力和电信运营商深度合作共赢,探索电力多种经营,具有有重大意义。
英文摘要:
      When the mobile base station and substation are built together, the electrical safety protection distance must be taken into account. In the paper, it’s analyzed that the disturbance voltage of the two cables in substation when the base station suffers the light strike, the substation switching operation and short circuit faults influencing on the base station grounding. According to the relevant national and international standards, the electrical parameters are calculated when the substation and mobile base station grounding grid connected in different ways and different distance to get the electrical safety protection distance. The conclusion provides a theoretical basis for engineering construction with the high practical value. Meanwhile, it is of great significance to develop the win-win co-operation of the power and telecommunications operators, to explore the diversified businesses of electric power.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd