文章摘要
基于神经网络数据融合方法的小电流接地选线装置的研制
Sduty on Non-effectively Grounded System Lault Line Dtection Instrument Based on Data Fusion of Neural Network
Received:June 28, 2014  Revised:September 10, 2014
DOI:
中文关键词: 配电网  小电流接地故障  数据融合  神经网络  ARM  故障选线
英文关键词: distribution  network,small  current grounding  fault,data  fusion,ARM,fault  line detection
基金项目:
Author NameAffiliationE-mail
WANG Shisheng Information Engineering School of Nanchang University 4764668@163.com 
guo ge* Information Engineering School of Nanchang University 4764668@163.com 
XIONG Lihua Information Engineering School of Nanchang University  
Hits: 1923
Download times: 1180
中文摘要:
      配电网中的单相接地故障是经常发生的一类故障,本文通过设计研究并安装一款基于神经网络数据融合方法的小电流选线装置来排查此类故障。装置利用BP神经网络良好的非线性拟合能力,结合故障后各线路的小波能量、五次谐波和有功功率作为特征值进行融合选线。根据故障选线的准确性和快速性对系统的要求,提出了一种基于ARM(Advanced RISC Machines)技术的软硬件平台,装置采用32位嵌入式ARM微处理器S3C2440作为诊断机的核心,以C8051F060作为前端采集器的控制核心,充分利用ARM出色的实时中断响应和快速的运算速度,很好的实现了综合智能选线算法。现场运行结果表明,该装置运行稳定,选线快速可靠,适应性强,是小电流接地系统中一种实用的选线装置。
英文摘要:
      Small current grouding fault frequently occurs in distribution network.In this paper,the design and installation of a new small current grouding line selection device is used to troubleshoot such fault.Device uses the nonlinear fitting ability of BP neural network,combined with wavelet energy,active power and fifth harmonic to determine the fault line.A design of hardware and software platform on ARM meeting to the requisition of reliability and rapidity in fault line detection is presented.ARM processor S3C2440 makes the controlling core of diagnostic mathine and C8051F060 makes the controlling core of the data acquisitionunit.The advantages of ARM,excallent real time interrupt response and high caculating speed,make the synthetical intellective algorithm to be fast processed in time.The operation test show that the device has good running stablity and fault detection is fast and reliable. It is a practical line selection device.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd