文章摘要
基于负序分量的分布集中式广域后备保护研究
A centralized-distributed Wide Area Backup Protection Study Based on Negative Sequence Component
Received:June 29, 2014  Revised:June 29, 2014
DOI:
中文关键词: 广域继电保护  负序功率  电压分布  故障方向
英文关键词: wide area protection,negative sequence flow, voltage distribution, fault direction
基金项目:
Author NameAffiliationE-mail
niehongzhan Northeast Dianli University  
WANG Fei* School of Electrical Engineering,Northeast Dianli University 1012549989@qq.com 
Yuan Xiao-dan School of Electrical Engineering,Northeast Dianli University  
Hits: 1731
Download times: 895
中文摘要:
      提出了一种基于负序分量的分布集中式广域后备保护方法。本文利用系统故障时线路负序电压的分布特点,通过对各母线负序电压的排序,确定由疑似故障母线和线路组成的疑似故障区,并采用分层搜索方法,首先对准疑似故障母线及线路关联IED处对应的负序功率方向进行判别,直至判定并切除故障母线或线路。该方法仅需将定义的准疑似故障区域的信息上传至决策中心,系统计算量和通信量大为减少,从而加快了故障元件的识别速度。算例仿真结果表明,该方法在高阻接地、潮流转移过负荷及转换性故障运行情况下均能良好动作,验证了此方法的有效性以及适用性。
英文摘要:
      A centralized-distributed wide area backup protection is presented on negative sequence component. This paper determines the likely faulty area composed of likely faulty buses and lines by sorting the negative sequence voltage of buses, based on the distribution of negative sequence voltage. A hierarchical searching algorithm is applied in this paper. Estimate the direction of negative sequence flow of the IEDs concerned with strongly suspected faulty buses and lines, until the faulty buses or lines are removed. This algorithm uploads only the message of strongly suspected faulty area to the decision center, reducing the calculated quantity and communication traffic and speeding up faulty elements identification. Simulation test illustrates the effectiveness and the adaptability when grounding resistance and flow transferring and cross-country fault happens.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd