文章摘要
智能变电站行波定位系统研发
Research of Traveling Wave Fault location System in the Smart Substation
Received:July 07, 2014  Revised:July 07, 2014
DOI:
中文关键词: 智能变电站  行波测距  IEC61850  电子式互感器  行波传感器
英文关键词: Smart substation  Traveling wave fault location  IEC61850  Electronic transformer  Traveling wave sense
基金项目:
Author NameAffiliationE-mail
Han Wei* Henan Electric Power Research Institute hnlhhw@126.com 
Shi Guang Henan Electric Power Research Institute  
Liu Lei Henan Electric Power Research Institute  
Zhao Wenpei Shenzhen Shuanghe Electric Co,Ltd  
Peng Jinfeng Shenzhen Shuanghe Electric Co,Ltd  
Hits: 1747
Download times: 926
中文摘要:
      为解决当前智能变电站行波测距装置遇到的困境,设计研发了一套智能变电站行波测距系统。介绍了智能变电站行波测距系统的构成,研发了满足IEC61850标准的行波测距主站,研制了不受PT/CT采样率限制的行波传感器,设计了基于纯硬件电路辨识行波的行波采集装置硬件方案及软件流程。并通过实验的方法验证了本系统的测距准确性,能够准确的定位故障距离。本系统可避免对电子式互感器进行改造,促进行波测距技术在智能变电站的应用及推广。
英文摘要:
      In order to solve the embarrassments of the traveling wave fault location device in the smart substation at present, we have developed a new traveling wave fault location system.This article introducd the structure of the traveling wave fault location system.It includes a master station which can meet the requirements of IEC61850 and a traveling wave sensor was developed which is not restricted by the PT/CT sampling rate.In addition, the hardware scheme and software process for the traveling wave data acquisition device were designed.This solution can avoid a modification of the electronic transformer and promote the application and popularization of traveling wave fault location technology in the smart substation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd