• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
含双馈风电场的电网节点脆弱性评估
Vulnerable Node Assessment of Power System With Double-fed Wind Farms
Received:July 14, 2014  Revised:July 14, 2014
DOI:
中文关键词: 风电并网  双馈发电机  连续脆弱性  脆弱节点  综合脆弱性评估
英文关键词: wind power  doubly-fed generator  continuous vulnerability assessment  fragile node  integrated vulnerability assessment
基金项目:
Author NameAffiliationE-mail
WANG Lan* Intelligent Electric Power Grid Key Laboratory of Sichuan Province,School of Electrical Engineering and Information,Sichuan University 972498847@qq.com 
LI Hua-qiang Intelligent Electric Power Grid Key Laboratory of Sichuan Province,School of Electrical Engineering and Information,Sichuan University  
CHEN Zhuo Intelligent Electric Power Grid Key Laboratory of Sichuan Province,School of Electrical Engineering and Information,Sichuan University  
XU Hai-qing Intelligent Electric Power Grid Key Laboratory of Sichuan Province,School of Electrical Engineering and Information,Sichuan University  
Hits: 1549
Download times: 783
中文摘要:
      随着风力发电的大力发展,风电出力的随机性、波动性以及其吸收无功的特点,使得风电并网后成为电网的一个扰动源,进一步对系统的脆弱性产生影响。文中结合静态能量函数模型和电气介数,提出一种能够反映节点的状态脆性和结构脆弱性的综合评估指标,同时将离散指标连续化,得到随时间变化而变化的综合评估指标。通过搭建含双馈风电场的电网模型进行仿真计算,得到随综合风速变化的节点综合评估指标的连续变化曲线,比较了不同接入点情况下的系统节点脆弱性的变化,并对结果进行分析。
英文摘要:
      With the development of wind power, it has the characteristics of stochastic volatility and absorbing reactive power on grid, so the wind power become a disturbances source of power grid, and further impact on the vulnerability of the system. This paper combined static energy function model with electrical betweenness and proposed a new set of comprehensive assessment indicators which reflect both the state of a node of vulnerability and fragility of the structure. At the same time, made discrete indicators serialization; got a set of comprehensive assessment indicator that changes with time. By building grid model with double-fed wind farm and simulating, this paper got a continuous curve that comprehensive assessment indicators changes with integrated wind, and compared different access points the changes in the vulnerability of the system nodes, and the results were analyzed.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd