110kV线路零序电流保护误动原因分析及对策
Cause analysis on zero sequence current protection maloperation of the 110kV line and its countermeasures
Received:July 14, 2014  Revised:July 16, 2014
DOI:
中文关键词: 线路保护  零序电流保护  误动  变压器  中性点间隙  方向元件
英文关键词: line protection  zero sequence current protection  maloperation  transformer  neutral gap  directional element
基金项目:
Author NameAffiliationE-mail
CHENG Zhen-he Xuzhou Power Supply Company,Jiangsu Xuzhou 221005 chengzhh@js.sgcc.com.cn 
LIU Gui-lin* Xuzhou Power Supply Company,Jiangsu Xuzhou 221005 jwddlgl@sina.com 
Hits: 1825
Download times: 770
中文摘要:
      徐州地区电网某220kV变电站一条110kV出线出口发生单相接地故障时导致多条110kV线路零序电流保护误动。故障线路单相接地时产生的零序电压造成该变电站其它非故障线路馈供的110kV变压器中性点放电间隙击穿,从而使非故障线路中流过反方向的零序短路电流是零序电流保护误动的原因。本文提出了110kV线路零序电流I、II保护增加方向元件,或者只使用零序电流末段保护的对策。
英文摘要:
      In Xuzhou power grid,a single-phase outlet grounding fault happened on the 110kV line of a 220kV substation.It led to zero sequence currentSprotection maloperation of several 110kV lines. When the single-phase grounding fault happened,the zero sequence voltage appeared. It resulted in the neutral gap’s breakdown of 110kV transformers which were connected to the non fault line. Consequently, zero sequence current in opposite direction flowed in theSnon fault line.That is the reason of zero sequence current protection maloperation. In order to preventing the occurrence of similar accidents, the article put forward two countermeasures.That is to add a directional element,or only to use the last segment for the zero sequence current protection of the 110kV line.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd