文章摘要
电子式互感器误差校准的研究
Research on Electronic Instrument Transformer Error Calibration
Received:July 14, 2014  Revised:July 14, 2014
DOI:
中文关键词: 电子式互感器  比值差  相位差  校准  测量
英文关键词: electronic instrument transformer, ratio error, phase displacement, calibrate, measure
基金项目:
Author NameAffiliationE-mail
ZHOU Li-ren* Shanghai Institute of Measurement and Testing Technology zhoulr@simt.com.cn 
PAN Yang Shanghai Institute of Measurement and Testing Technology  
ZHU Li Shanghai Institute of Measurement and Testing Technology  
ZHANG Guo-zhong Shanghai Institute of Measurement and Testing Technology  
Hits: 1516
Download times: 755
中文摘要:
      电子式互感器是智能电网建设的关键设备之一,其性能直接影响到数字化变电站的安全和经济效益,也是电能计量准确的必要条件。电子式互感器的输出与传统互感器不同,分为数字输出和模拟输出两种,因此传统的互感器校准方法已经不适用于校准新型的电子式互感器。本文以模拟量输出的互感器为例,创新性地提出了采用精密分流器和示波器测量比值差和相位差,并对校准数据进行了验证,测量结果满意。
英文摘要:
      Electronic instrument transformer is one of the key equipments for the construction of smart grid, of which performance directly influences safety and economic benefit of digital substation and the necessary condition of accurate power measurement. The output signal of electronic instrument transformers is different from that of conventional electromagnetic transformers, which is classified into digital output and analogue output. Therefore, conventional calibration methods are not suitable for testing electronic instrument transformers. This paper takes electronic instrument transformer with analogue output as example; innovatively put forward employing precise shunt and oscilloscope to measure ratio error and phase displacement. Meanwhile, the data were verified and the results were satisfied.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd