• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
计及风电场集电网络等值模型的仿真研究
Simulation Research on Equivalent Model of Wind Farm Collector Network
Received:July 27, 2014  Revised:July 30, 2014
DOI:
中文关键词: 风电场  双馈感应风力发电机  等值模型  集电网络
英文关键词: wind  farm, doubly  fed induction  generator, equivalent  model, collector  network
基金项目:
Author NameAffiliationE-mail
LIU Han-jiang* College of Energy and Electrical Engineering,Hohai University 18251910537@163.com 
PAN Wen-xia College of Energy and Electrical Engineering,Hohai University  
zhangchengcheng State Grid Electric Power Company of Liaocheng  
liumingyang College of Energy and Electrical Engineering, Hohai University  
Hits: 1443
Download times: 772
中文摘要:
      以双馈感应发电机组构成的风电场为研究对象,考虑了风力发电机与集电网络的等值,提出两种模型,研究了单机加权等值与等功率损耗结合模型,降阶变尺度等值与并联化结合模型。针对风电场机组参数完全相同的算例,利用PSCAD/EMTDC建立了风电场的不同等值模型,对风速扰动和PCC处发生电压跌落故障下的风电场暂态特性进行了比较分析,研究结果验证了等值模型的正确性。
英文摘要:
      The thesis focuses on wind farm consisting of doubly fed induction generators, considering the equivalence of wind power generator and collector network, put forward two models, study the combination model of single weighted equivalent and equivalence power loss, the combination model of reduced-order re-scaled and parallel connection aimed transformation. Regarding the wind turbine generator system with identical parameters, using PSCAD/EMTDC to establish the different equivalent model of wind farm, a comparative analysis of the transient characteristics of wind velocity perturbation and the voltage drop of PCC, the results verify the validity of the equivalent model.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd