• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电力电压互感器在线群校准技术研究
Research of Group Online Error calibration for Power Voltage Transformer
Received:October 10, 2014  Revised:December 11, 2014
DOI:
中文关键词: 电压互感器,在线群校准,电压标准器,采集板,准确度等级
英文关键词: voltage transformers, group online error calibration, standard voltage device, acquisition board, accuracy degree
基金项目:
Author NameAffiliationE-mail
WANG Huan* China Electric Power Research Institute wanghuanwuhan@163.com 
XIANG Qiong China Electric Power Research Institute  
DU Yan China Electric Power Research Institute duyan3@epri.sgcc.com.cn 
YU Chun-yu China Electric Power Research Institute  
Hits: 2420
Download times: 839
中文摘要:
      基于一次设备状态检修出现的问题,提出电压互感器在线群校准概念。首先,针对在运变电站的实际情况,阐述了在线校准中使用的电压标准器的选择及接线方式。然后,介绍群校准系统的设计原理与结构,并对研制的在线群校准装置进行了多路信号同步采集的能力测试,试验数据表明该系统在运行时引入的误差优于0.05%,满足对0.2级电压互感器进行在线群校准的能力。最后,针对变电站现场测试特点,提出在线群校准工作时需要对一次压降、二次压降、二次负荷进行规定,以提高在线误差校准数据的可靠性。
英文摘要:
      The concept of group online error calibration for voltage transformer is proposed for these problems of primary equipment condition-based maintenance. First, the choice of voltage standards for group online error calibration is introduced base on the actual operation of substation. Second, the principle and structure of group online error calibration is illustrated. What’s more? Two groups of test for multi-channel signal acquisition at the same time have been done for the online calibration system which is developing in the paper. The experimental data show that the error which is produced by the calibration system is less than 0.05% at run time and it can meet the ability to 0.2 level calibration voltage transformer. Finally, in order to improve the reliability of online calibration, provisions for firstly and secondary voltage drop, second load are carry out accord characteristics of field test.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd