• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
双馈风机孤岛模式下恒压恒频运行控制策略*
The CVCF Control Strategy for Stand-Alone Doubly Fed Induction Generator
Received:October 28, 2014  Revised:April 08, 2015
DOI:
中文关键词: 双馈风机,恒压恒频,孤岛运行,定子磁场定向
英文关键词: DFIG, CVCF, stand-alone, stator-flux-oriented
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
Author NameAffiliationE-mail
ZHANG Yan-bing Guizhou University 412048431@qq.com 
HAO Zheng-hang* Guizhou University 983135026@qq.com 
NI Yuan Guizhou University  
CHEN Kang-bo Guizhou University  
XUN Shuo-shuo Guizhou University  
Hits: 2402
Download times: 678
中文摘要:
      根据双馈发电机的数学模型,在强迫定向的定子磁场控制策略的基础上,改造DFIG励磁变频器控制策略,实现孤岛下双馈风机恒压恒频运行。技术思路:通过调节转子磁场旋转频率控制定子电压频率,调节转子磁通幅值控制电机内电势。控制转换开关,使得双馈风机孤岛下借助蓄电池进行起励,之后投入直流电容并退除蓄电池,实现双馈风机孤岛恒压恒频运行。并利用Matlab/Simulink对所提出的方案进行了仿真,结果表明该方案的可行性。
英文摘要:
      From the beginning of mathematics model of doubly fed generator, the excitation control for stand-alone doubly fed generator was remade that based on forced stator-flux-oriented control strategy, ensure that the stand-alone doubly fed generator work properly at constant voltage constant frequency(CVCF) operation. Technical ideas: Control the frequency of stator voltage by adjusting the rotating frequency of the rotor magnetic field. Adjust the rotor flux amplitude for controlling the stator internal potential. By controlling the switches, ensure the stand-alone doubly fed generator running by itself at CVCF operation. A model was build that simulated in the Matlab/Simulink, the results show that the control strategy is feasible.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd