• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
计量用低压电流互感器自动化检定线的检定质量监控
Verification quality monitoring of metering low-voltage current transformer automatic verification line
Received:October 30, 2014  Revised:October 30, 2014
DOI:
中文关键词: 低压电流互感器  自动检定  质量监控  测量不确定度
英文关键词: low-voltage current transformer  automatic verification line  quality monitoring  measurement uncertainty
基金项目:
Author NameAffiliationE-mail
ZHOU Li-hua* State Grid Anhui Electric Power Research Institute,Hefei,230601 liihaa@sina.com 
Hits: 1739
Download times: 888
中文摘要:
      质量监控是检定/校准实验室保证其检定/校准的数据和结果准确可靠所采取的作业技术和活动。自动化检定流水线已广泛应用于省级电力计量中心的检定生产中。与传统人工检定台体相比,计量用低压电流互感器自动化检定线因二次端子接触不良等原因导致的检定质量风险更大,需要对其进行有效的检定质量监控。本文根据质量监控的一般方法,结合自动化检定线的特点,提出了基于检定误差限值倍数的监控判据和方法,并对其进行了实验验证。确保检定设备的可控、在控,检定结果的准确、可靠。
英文摘要:
      Quality monitoring is a method and activities used by verification /calibration laboratories to ensure its verification/calibration data and results are accurate and reliable. Automatic verification line has been widely used in provincial electric power metering center in production. However, verification quality risks caused by such as poor contact of secondary terminals in automatic verification line is bigger than traditional manual testing apparatus, so effective verification quality monitoring is necessary for low-voltage current transformer automatic verification line. According to the general methods for quality control, this paper proposes a monitoring criterion and method based on multiple error limit of verified current transformer, and experimentally verified this criterion and method. Which ensures test equipment is controllable and in control, test results are accurate and reliable.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd