• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于不同运行工况下双馈风力发电机电磁场计算与分析
Based on different conditions DFIG electromagnetic field calculation and analysis
Received:November 25, 2014  Revised:November 25, 2014
DOI:
中文关键词: 双馈风力发电机  不同运行工况  气隙磁密  电磁场分析  有限元分析
英文关键词: doubly fed induction generator (DFIG)  different operating conditions  Flux density  Electromagnetic Analysis  finite element analysis
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
Author NameAffiliationE-mail
men yaping College of Electrical Engineeringof Xinjiang University menyaping.gs.gg@163.com 
zhang xinyan* College of Electrical Engineeringof Xinjiang University  
zhao boyao Da Tang 803 Power Plants  
huang chi College of Electrical Engineeringof Xinjiang University  
Hits: 1384
Download times: 680
中文摘要:
      风力发电机组在正常运行过程中,很容易受到外界扰动,分析研究不同运行工况对风力机组的影响具有重要的意义。基于ansys有限元分析软件,建立某风电场1.5MW双馈风力发电机的2维模型,通过对正常运行工况、电网电压三相不平衡以及风速突变工况下双馈发电机气隙磁密和磁力线分布进行仿真和分析,得到不同运行工况对双馈发电机的影响。仿真结果表明:电网电压三相不平衡和风速突变工况下,双馈发电机气隙磁密都会发生变化,而且前者气隙磁密发生了明显的畸变,漏磁增加,损耗增加。
英文摘要:
      During normal operation, it is very vulnerable to external disturbances, so the analysis and research of different operating conditions have significant impact on wind turbines. Based on finite element analysis software ANSYS, a two-dimensional electromagnetic field model of doubly fed induction generator (DFIG), whose capacity is 1.5MW and is installed in a certain wind farm, is established. During normal operating conditions, grid voltage unbalance and wind speed mutation conditions to simulate and analyze the doubly-fed generator air gap flux density, magnetic field lines distribution,we will obtain the effects of different conditions on the doubly-fed generator. The simulation results show that grid voltage unbalance conditions and wind speed mutation conditions, doubly-fed generator and air gap flux density will change, but a significant distortion occurred in the former flux density, magnetic flux leakage increases, the loss increases.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd