• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
电网电压不平衡条件下并网逆变器的动态相量模型
Dynamic Phasor Model of Grid-connected Inverter with Unbalanced Grid Voltage
Received:December 02, 2014  Revised:January 27, 2015
DOI:
中文关键词: 微电网  不对称  逆变器  动态相量模型  电磁暂态模型
英文关键词: microgrid  unbalanced  inverter  electromagnetic transient model  dynamic phasor model
基金项目:
Author NameAffiliationE-mail
GAO Ming-hai* School of Electrical Engineering,Wuhan University gaominghai0@163.com 
SUN Jian-jun School of Electrical Engineering,Wuhan University  
HU Wei School of Electrical Engineering,Wuhan University  
ZHA Xiao-ming School of Electrical Engineering,Wuhan University  
Hits: 1601
Download times: 1149
中文摘要:
      为适应电网电压不对称条件下微电网快速精确仿真和分析控制的需要,采用了一种新的建模方法。基于时变傅立叶级数的动态相量法,分别取正负序分量的一阶动态相量,无需进行2倍频滤波,减少了模型的计算量。建立了电网电压不平衡条件下并网逆变器的动态相量模型,并在Matlab/simulink中建立三相电网电压不平衡条件下逆变器输出的详细时域模型,对两个模型进行仿真分析。通过对两个模型的仿真结果进行比较分析,结果表明所提的在电网电压不平衡条件下动态相量模型的正确性和有效性,为并网逆变器和微电网的不对称分析和控制提供了一种新方法。
英文摘要:
      In order to meet the needs of fast and precise simulation and control analysis of the microgrid with unbalanced grid voltage, a dynamic phasor which is based on time-varying Fourier series is presented in this paper. By obtaining the first order dynamic phasor of the positive and negative sequence components respectively,the caculation of the model is significantly reduced by omiting the use of 2-octave filter.The dynamic phasor model and electromagnetic transient model of grid-connected inverter with unbalanced grid voltage are established.By comparing the simulation result of the two models,the correctness and effectiveness of the dynamic phasor model is demonstrated,which providing a new method for the analysis and control of the unbalanced operation of grid-connected inverter and microgrid.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd