风电场汲流效应对配电网故障电流的影响
Impacts of The Shunting Effect of Wind Farm on Fault Current Characteristics of Distribution Network
Received:December 18, 2014  Revised:March 12, 2015
DOI:
中文关键词: 风电场,配电网,继电保护,汲流效应
英文关键词: wind farm  distribution network  protective relaying  shunting effect
基金项目:新疆维吾尔自治区自然科学基金资助项目(2012211A002)
Author NameAffiliationE-mail
CHANG Qing* Engineering Research Center for Renewable Energy Generation & Grid Control , Xinjiang University 398359790@qq.com 
LI Fengting Engineering Research Center for Renewable Energy Generation & Grid Control , Xinjiang University  
ZHOU Weiji College of Mechanical and Electrical Engineering, Shihezi University  
Hits: 2184
Download times: 518
中文摘要:
      首先研究了风电场故障电流特性及其影响因素。然后考虑过渡电阻,推导了风电场接入点上游故障电流与风电场输出电流的数学关系式,分析了风电场对上游故障电流的分流效应。最后以PSACD/EMTDC为仿真平台,搭建了含风电场的配电网模型,仿真研究了风电场接入配电网对接入点上游故障电流和继电保护的影响。研究表明,由于风电场汲流效应,接入点上游的故障电流会因为风电场的接入而减小,且严重时会导致上游电流保护I段的保护范围减小,II段保护灵敏度减小,容易造成保护的拒动。
英文摘要:
      Firstly,the characteristics of the fault current of wind farms and its influencing factors are researched.Then considering the transition resistance ,the relational expression between fault current at the upstream side of wind farm network-connected position and short-circuit current offered by the wind farm is derived. Impacts of the shunting effect of wind farm on system fault current is analyzed. A simulation model of distribution network containing wind farm is built on the platform of PSCAD/EMTDC, and influence of wind farm on fault current and protective relaying at the upstream side of wind farm network-connected position are studied are simulated and studied.Research results show that on account of the shunting effect of wind farm, the fault current at the upstream side will decrease.when the situation is serious,it is connected to the system and protective relaying will refuse action because of the shortened I-zone and the Insensitive II-zone at the upstream side of wind farm network-connected position.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd