文章摘要
基于有限元的超高压输电线路电场的数值分析与测量
Numerical analysis and measurement of the electric field of EHV transmission lines based on finite element
Received:December 23, 2014  Revised:March 26, 2015
DOI:
中文关键词: 输电线路  电场分布  Ansoft maxwell  电磁环境
英文关键词: Transmission line  Electric field distribution  Ansoft maxwell  Electromagnetic environment
基金项目:
Author NameAffiliationE-mail
Peng Pai* Faculty of Automation ,Guangdong University of Technology paipaismile@sina.com 
Cheng Hanxiang Faculty of Automation ,Guangdong University of Technology  
Chen xingcan Faculty of Automation ,Guangdong University of Technology  
Yang jian Faculty of Automation ,Guangdong University of Technology  
Li lei Faculty of Automation ,Guangdong University of Technology  
Hits: 1884
Download times: 1127
中文摘要:
      为探讨500kV超高压输电线路下的电场分布问题,在验证了有限元电磁场分析软件Ansoft maxwell的有效性后,建立了同塔双回输电线路模型。主要分析与研究了相导线对地高度、分裂导线结构尺寸等因素对电场特性的影响,以及线路发生故障或停电检修时电场分布的变化规律,这为降低输电线路周围电场和对电磁环境的优化提供理论依据和方法,同时对停电检修线路注意事项提供一定的参考。
英文摘要:
      In order to investigate the electric field distribution problems under 500kV EHV transmission lines and establish the same tower double circuit transmission line model after verifying the effectiveness of the finite element electromagnetic field analysis software Ansoft maxwell . The paper mainly analyze the influence of the phase conductors to ground height , split wire structure size and other factors on the characteristics of the electric field , and the variation of the line electric field distribution when a fault occurs or outage maintenance, which is to provide a theoretical basis and methods for reducing the transmission lines around the farm and the optimization of the electromagnetic environment, At the same time ,it provides a reference for power line maintenance considerations.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd