• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
单相LCL并网逆变器多环控制策略的研究
Research on Multiple-loop Control Strategy for Single-phase Grid-connected Inverter
Received:December 23, 2014  Revised:December 23, 2014
DOI:
中文关键词: 电子负载  LCL滤波器  PR控制器  多环控制
英文关键词: Electronic  load, LCL  filter, PR  controller, multi-loop  control
基金项目:
Author NameAffiliationE-mail
(HOU Li-jian* Ordnance Engineering College houlijian1205@163.com 
ZHU Chang-qing Ordnance Engineering College  
CHEN Ya Tianjin University  
YAN Xue-fei) Ordnance Engineering College  
Hits: 1940
Download times: 667
中文摘要:
      本文阐述了传统双环单相VSR控制策略存在的缺点,在此基础上,介绍了PR控制器的优势,用PR控制器代替PI控制器,同时采用陷波器校正的有源阻尼方法抑制LCL滤波器的谐振峰值,并加入电压前馈控制,构成了包含电压外环、并网电流控制环、电容电流环的多环控制系统。最后设置控制器参数,在Matlab/Simulink环境下搭建了仿真模型,仿真结果表明,该方案能够有效控制并网电流,滤波效果良好,抗电网电压扰动能力强,实现了并网电流和电网电压同步的控制目的,验证了其可行性和优越性。
英文摘要:
      This paper describes weakness of the control strategy of traditional double-loop for single-phase VSR, and based on it, introduces the advantages of PR controller, so as to PR controller replaces the PI controller. At the same time, the method of active damping, with the trap filter correction, is used to suppress the resonance peak value of the LCL filter. Moreover, the voltage feed-forward control method is put into use, as a result, the control method is a strategy that contains voltage loop,grid-connected current loop and capacitor current loop. Finally the control parameters are set up, and the model of simulation are conducted in with the help of Matlab/Simulink. The simulation results indicate that the strategy can control the grid-connected current well, and it has a good effect of filtering, meanwhile it also has strong ability of anti the disturbance of the grid voltage.The target, electrical energy can be fed to the grid in the way of unit power factor, is achieved, that is to say the feasibility and the superiority are verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd