• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于改进射影控制的柔性直流输电广域阻尼控制
VSC-HVDC Wide-Area Damp Controller Design Based on Improved Projective Control
Received:December 25, 2014  Revised:December 25, 2014
DOI:
中文关键词: VSC-HVDC,TLS-ESPRIT辨识,极点配置,射影控制,阻尼控制器
英文关键词: VSC-HVDC, TLS-ESPRIT  identification, pole-placement, projective  control, damping  controller
基金项目:国家重点基础研究发展计划(973计划)(2013CB228204);国家电网公司大电网重大专项资助项目课题(SGCC-MPLG001-027-2012)。
Author NameAffiliationE-mail
GUO Lei* School of Electrical Engineering and Information,Sichuan University gleisky@163.com 
ZHANG Yingmin School of Electrical Engineering and Information,Sichuan University  
LI Xingyuan School of Electrical Engineering and Information,Sichuan University  
Hits: 2232
Download times: 685
中文摘要:
      针对包含柔性直流输电的交直流互联系统之间存在低频振荡,且一般的直流附加阻尼控制器阶数较高,影响了控制的实用性和有效性,文中提出将基于射影定理的降阶控制器设计方法应用于VSC-HVDC输电系统的阻尼控制器设计当中。首先通过TLS-ESPRIT算法辨识出系统的振荡特性和传递函数;再根据极点配置方法和Ackermann公式得到系统的状态反馈增益矩阵;最后通过改进射影控制定理,保留参考全状态闭环系统的主导特征值,输出低阶射影控制器。在PSCAD/EMTDC中的一个包含柔性直流输电的四机两区域模型中,对不同励磁增益参数下无附加控制器和有时滞射影控制器下的系统进行仿真分析。结果表明,所设计的射影控制器具有较好的阻尼特性和鲁棒性。
英文摘要:
      In allusion to the low frequency oscillation existed in the AC/DC power system with VSC-HVDC system contained, the general HVDC additional damping controllers have higher order of matrix affect the practicability and availability, a kind of reduced-order controller design method based on projective control theorem is proposed to be used in the design of damping controller in VSC-HVDC transmission system. In the first, the oscillation character and transfer function are identified by the TLS-ESPRIT algorithm. Besides, the state-feedback matrix is
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd