电流互感器自动化检定系统二次负荷测试及分析
Measure and Analysis on Secondary Burden of Metering Current Transformer Automatic Testing System
Received:February 03, 2015  Revised:October 16, 2015
DOI:
中文关键词: 电流互感器  自动化检定系统  二次负荷  测试  分析;改进
英文关键词: current  transformer, automatic  testing system, secondary  burden, measure, analysis,improvement
基金项目:
Author NameAffiliationE-mail
DING Tao* Henan Electric Power Research Institute dingtao_cn@163.com 
Shao Huailing Henan Electric Power Research Institute dingtao_cn@163.com 
He Zhiqiang Henan Electric Power Research Institute dingtao_cn@163.com 
ZhANG Wei Henan Electric Power Research Institute  
LI Hua-dong Henan Electric Power Research Institute  
LI Lei Henan Electric Power Research Institute  
Hits: 2009
Download times: 1108
中文摘要:
      简介了互感器校验仪法及伏安相位法两种二次负荷测试方法,并对电流互感器自动化检定系统各工位的二次负荷进行了测试。测试结果表明,二次回路导线的阻抗均超过60mΩ,最大值达到了100mΩ;当电流负载箱置2.5VA时,测试的二次负荷实际值与额定值的偏差绝大多数超过5%,最大偏差达到了19%。发现了二次回路继电器接点的接触电阻和二次自动接线机构压接不紧是主要原因,分析了其对二次负荷、互感器误差的影响。最后提出了具体的改进措施,减小了二次回路的阻抗,提高了互感器的检定质量。
英文摘要:
      This paper briefly introduces two experimental methods of transformers test set and voltage ampere phase, secondary burden of work stations is measured in the metering current transformer automatic testing system. The result shows that the wire resistance is more than 60mΩ on average,100 mΩ up to the max resistance value and most of relative errors between the actual burden and the nominal burden exceed 5% , 19% up to the max relative error while the volume of the burden box is 2.5VA. The fact that contact resistance of relays and poor contact between terminals of current transformer and connection mechanism is the main reason. It analyses influences on secondary burden and error of current transformer. Finally, some improvement measures are suggested for the system. This decreases secondary loop impedance and improves the test quality of current transformer.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd