• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
保护用超大电流互感器的屏蔽方案分析
The Analysis on Shielding Methods of Protective Heavy Current Transformer
Received:February 09, 2015  Revised:February 16, 2015
DOI:
中文关键词: 保护用电流互感器  屏蔽  测量误差  发热量
英文关键词: protective heavy current transformer  shielding method  measurement error  heat
基金项目:
Author NameAffiliationE-mail
zhanglu* State Grid Jibei Electric Economic Research Institute 794116397@qq.com 
lishunxin aaa  
lihaibin aaa  
zhuzhengjia aaa  
songla aaa  
shenhuiqi aaaa  
zhangsong aaaa  
Hits: 1510
Download times: 529
中文摘要:
      本文对保护用超大电流互感器的屏蔽方法进行了对比分析,针对平衡绕组常用的两种连接方式——“反极性串”和“四段全并”,先利用有限元数值计算软件ANSYS仿真计算出各绕组的电感和彼此间的互感,进而通过分析其线性电路模型,求解各绕组的电流及测量误差;通过比较两种屏蔽方案对杂散磁通的屏蔽效果和发热量,给出了优选建议。
英文摘要:
      The paper compares two shielding methods, when shielding coils are in reverse-polarity series connection and in parallel connection, calculates the inductance with ANSYS, and analyses the linear circuit model, to obtain the coils" current and measurement error. Then the paper compares the shielding effects and heat, to make the judgment that which method is better.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd