九开关分布式并网系统抑制共模电流的措施分析
Analysis of Common-mode current attenuation of nine-switch grid-connected system
Received:March 09, 2015  Revised:August 13, 2015
DOI:
中文关键词: 九开关变换器  光伏并网发电系统  共模电压  共模电流
英文关键词: nine-switch converter  photovoltaic grid-tied power generation system  common-mode voltage  common-mode current  
基金项目:
Author NameAffiliationE-mail
Zhou Liwei School of Electrical Engineering,Shandong University 18769785783@163.com 
Tian Haiming Changle Power Supply Company  
Xing Lei Changle Power Supply Company  
Wang Chao Qingdao Power Supply Company  
Gao Feng* School of Electrical Engineering,Shandong University fgao@sdu.edu.cn 
Hits: 1907
Download times: 593
中文摘要:
      一种应用于集成式光伏并网系统的九开关变换器相比于传统的集成并网拓扑结构节省了25%的半导体器件数量,降低了变换器的体积以及成本,但是如果未考虑系统共模电流的抑制措施,那么高频波动的共模电压将会激发共模漏电流,进而对人身和设备的安全产生威胁。文中首先对这种九开关电路结构进行了介绍,然后详细分析了这种紧凑型的分布式发电系统的共模电压回路,并对九开关拓扑结构中的共模电路进行了等效简化,最后在得出的简化模型的基础上提出抑制共模电流的新型九开关拓扑结构,并搭建了九开关电路仿真模型和实验电路进行验证分析。
英文摘要:
      Compared to the traditional back-to-back twelve-switch converter, a kind of nine-switch converter applied to the distributed energy systems saves 25% of the switch count. It reduces the volume and cost of the converter, but will cause serious problem of high value of common-mode current. This paper analyzes the common-mode voltage circuit of the compact integrated energy systems in detail and also equivalently simplifies the common-mode circuit. Finally, measures to reduce the common-mode current are proposed based on the simplified model. The simulation model and experimental prototype of the nine-switch topology are built to validate the theoretical findings.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd