文章摘要
一种新型的双向全桥直流变换器控制策略
A novel??control strategy of bi-directional?full bridge DC/DC converter
Received:March 09, 2015  Revised:May 18, 2015
DOI:
中文关键词: 双向全桥  回流功率  偏磁抑制  双闭环控制
英文关键词: bi-directional full-bridge, power circulating flow , magnetic bia Inhibition,double closed loop control
基金项目:广西科学与技术开发攻关项目(桂科攻:14122007-1);广西制造系统与先进制造技术重点实验室项目(13-051-09-001Z)
Author NameAffiliationE-mail
huangzhichao Guilin University of Electronic Technology hzc8021@126.com 
huangxiangli* Guilin University of Electronic Technology 247945465@qq.com 
liaozhijian Guilin University of Electronic Technology  
Hits: 2053
Download times: 858
中文摘要:
      隔离型双向全桥直流变换器在传统移相控制策略中,存在功率回流现象,并且由于变换器特性参数不一致将使得变压器初级产生直流分量而导致偏磁问题。针对此,提出了一种新型的PWM加移相控制策略,完全消除了功率回流和偏磁现象。给出了偏磁抑制过程,对隔离型双向全桥直流变换器运行时各模态进行了运行特性分析,并在Psim软件中对其进行建模仿真。仿真结果表明,将新型PWM加移相控制策略应用于隔离型双向全桥直流变换器中,能对直流偏磁以及功率回流进行有效抑制,证明了所提出方法的正确性和可行性。
英文摘要:
      With the traditional phase-shift control strategy using in isolated full-bridge bi-directional DC/DC converter , power circulating flow phenomena is exist. Because of the difference of the Converter’s characteristics, the primary side of the transformer will cause the DC component. Magnetic bias problem will be caused by the DC component finally. According to this phenomena, a new kind of PWM plus phase-shift control strategy is put forward in this paper. The phenomena of power circulating flow and magnetic bias are controlled completely with that strategy. The control process of magnetic bias has been given. Each modal’s running characteristics in the isolated full-bridge bi-directional DC/DC converter has been analyzed and the model has also been built in Psim software.The simulation results show that the new kind of PWM plus phase-shift control strategy using in the isolated full-bridge bi-directional DC/DC converter can restrain the power circulating flow and magnetic bias. The correctness and?feasibility of the new method has been verified.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd