文章摘要
低压抗直流电流互感器及检测装置研究
Research on Low Anti-DC Current Transformer and its Detection Device
Received:March 16, 2015  Revised:April 24, 2015
DOI:
中文关键词: 抗直流分量  检测装置  电流互感器
英文关键词: anti DC component  detection device  current transformer
基金项目:
Author NameAffiliationE-mail
JIN Shao-ping State Grid Jiangxi Electric Power Research Institute 13870881746@139.com 
LI Min* State Grid Jiangxi Electric Power Research Institute liminbest86918@126.com 
LIU Jian State Grid Jiangxi Electric Power Research Institute  
LI Dong-jiang State Grid Jiangxi Electric Power Research Institute  
WANG Xun State Grid Jiangxi Electric Power Research Institute  
NIE Fang-ming State Grid Jiangxi Electric Power Research Institute  
LI Xin State Grid Jiangxi Electric Power Research Institute  
TANG Xin-yu State Grid Jiangxi Electric Power Research Institute  
Hits: 2253
Download times: 824
中文摘要:
      针对传统低压电流互感器在直流分量负荷下存在传变误差大的技术缺陷,分析了直流分量导致传统电流互感器失准的机理,研制了低压抗直流分量电流互感器,并提出了电流互感器抗直流性能检测方法,在此基础上研制出电流互感器抗直流性能检定装置。实验证明研制的抗直流分量电流互感器具有较好的抗直流性能,能满足现场运行要求。
英文摘要:
      Aiming at the technical defects of large transfer error of traditional low-voltage current transformer with DC component load, the misalignment mechanism of the DC component causes the traditional current transformer was analyzed. A low-voltage current transformer of anti half wave DC was developed ,and proposed a detection method for anti DC performance of current transformer. Based on the method ,an anti-DC performance verification device of current transformer was developed .The experiment proved that the developed anti DC component current transformer with good performance and can satisfy the field operation requirements.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd