牵引变压器功率计量误差分析
Error analysis of measuring traction transformer power
Received:April 11, 2015  Revised:April 11, 2015
DOI:
中文关键词: 负序  阻抗匹配  电压平衡  无功计量  误差分析
英文关键词: negative  sequence impedance  matching voltage  balance measurement  of reactive  power error  analysis
基金项目:]:福建省教育厅中青年教师教育科研项目(JB14158)
Author NameAffiliationE-mail
jiang hui ying* Fujian college of Water conservancy and Electric power liangerjhy@163.com 
xu jian an Fujian college of Water conservancy and Electric power  
xu mu zheng Fujian college of Water conservancy and Electric power  
Hits: 1954
Download times: 868
中文摘要:
      分析了斯科特接线、 Y/V接线平衡变压器无功功率,有功与无功功率测量的误差。当牵引变压器二次负荷不平衡时,无论在一次侧或二次侧测量无功公论均存在误差;斯科特变压器当二次不平衡时,一次侧测量有功功率也有误差。通过理论计算和数字仿真,得到了在低压侧计量无功结果较实际值偏大及一次侧测量有功功率偏小的结论。
英文摘要:
      This article analyzes the Scott connection, Y/V connected balance transformer wattless power, active power and wattless power measurement error. When the secondary load of the traction transformer is out of balance, there exist errors in the measurement of one side or two side wattless opinion; when the Scott transformer is unbalanced for the second time, errors in a side active power measurement also exist. Thus I come to a conclusion by means of the theoretical calculation and numerical simulation that in the low-voltage side of the measurement without power was larger than actual value and a side active power measurement is small.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd