文章摘要
一种推挽式变换器的漏感影响研究
Study on the effects of leakage inductance in a push-pull converter
Received:April 14, 2015  Revised:June 11, 2015
DOI:
中文关键词: 推挽式变换器  等效模型  漏感  能量回馈
英文关键词: push-pull  converter, equivalent  model, leakage  inductance, energy  feedback
基金项目:
Author NameAffiliationE-mail
Zheng Changming College of Information and Control Engineering,China University of Petroleum jsxzzcm@126.com 
Zhang Jiasheng* College of Information and Control Engineering,China University of Petroleum  
Chen Rui College of Information and Control Engineering,China University of Petroleum  
Zhu Chenxing College of Information and Control Engineering,China University of Petroleum  
Zheng Wei College of Information and Control Engineering,China University of Petroleum  
Hits: 1787
Download times: 1102
中文摘要:
      根据磁势平衡原理,研究了一种带桥式整流输出的推挽式变换器的工作波形及性能影响因素,主要结合变压器激磁电感和漏感效应,建立了变换器等效电路模型和数学解析模型,详细讨论了激磁电感跨接在变压器原边两绕组之间时,推挽变换器无漏感和漏感等效于副边侧时的物理关系和理论波形。深入分析了漏感对开关管端电压、电路输出电压和能量回馈等方面造成的影响及消除方法。通过Matlab仿真验证了有关模型及理论分析结果的正确性。
英文摘要:
      According to the principle of magnetic potential balance, the operating waveforms and effects on performance of the push-pull converter with bridge rectifier output circuit are analyzed. Combined with magnetizing inductance and leakage inductance effects of transformer, equivalent circuit model and mathematical analytical model of the converter are established. The physical relationships and theoretical waveforms of push-pull converter with and without secondary side equivalent leakage inductance when the magnetizing inductance is placed between two primary windings of the transformer are discussed. The effects of leakage inductance on terminal voltage of the switch, output voltage and energy feedback of the circuit and their elimination methods are deeply studied. The Matlab simulation verifies the correctness of the correlation model and theoretical results.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd