文章摘要
基于加权灰靶理论的隔离开关健康状态评估
Health Status Evaluation of DisconnectorBased on Weighted Gray Target Theory
Received:April 16, 2015  Revised:August 19, 2015
DOI:
中文关键词: 隔离开关  运行可靠性  灰靶理论  层次分析法  健康状态等级  
英文关键词: disconnector, reliability, gray  target theory, analytic  hierarchy process, health  status level
基金项目:
Author NameAffiliationE-mail
CHENG Wen-ping* School of Electric Power.SCUT nirvanaphenix@163.com 
YU Tao School of Electric Power.SCUT taoyu1@scut.edu.cn 
YIN Hua-jie School of Electric Power.SCUT  
Hits: 1917
Download times: 640
中文摘要:
      针对隔离开关可靠性的研究缺少定量计算评估,提出了一种定量计算评估隔离开关运行可靠性的方法,该方法采用灰靶理论对隔离开关状态样本数据进行整合,并结合层次分析法确定状态指标量的权值实现对隔离开关的健康状态定量分级。并以南方电网江门供电局投入运行的隔离开关为例,计算出隔离开关的健康状态等级,其结果符合实际情况,表明了该方法具有一定的实际工程意义,可以为隔离开关运行维护和检修提供一定的指导。
英文摘要:
      According to the research of disconnector reliability evaluation is lack of quantitative calculation, so in this paper , we proposed a method that can evaluate reliability of disconnector in quantitatively, The method uses the gray target theory to integrate state sample data of disconnectors and uses analytic hierarchy process (AHP) to determine the amount of state index weights. At last, combining gray target theory with AHP together to achieve the health status of disconnector quantitative classification. we apply this method to the disconnector in Jiangmen Power Supply Bureau of China Southern Power Grid as an example and the result of the calculation is fit to the real situation, which means the method proposed in this paper is effective and has some practical engineering significance. To some extent , it can guide the maintenance of disconnector.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd