文章摘要
基于接地电流高压电缆交叉互联故障分析
Analysis of#$NBSthe cross–bonded failure of high voltage cable#$NBS#$NBS based on grounding#$NBScurrent#$NBS
Received:April 17, 2015  Revised:May 06, 2015
DOI:
中文关键词: 高压电缆  交叉互联  接地电流  ATP—EMTP仿真
英文关键词: high-voltage cable  cross –bonded  fault analysis  ATP-EMTP simulation
基金项目:
Author NameAffiliationE-mail
CHAI Yu-hua* Northeast Agriculture University yhchai@163.com 
Gong Yanjiang Northeast Agriculture University 444108562@qq.com 
Yang Gang Harbin electricity power supply company,Harbin  
Wang Yunhe Northeast Agriculture University  
Zhang Hanyu Northeast Agriculture University  
Liu Ziqing Northeast Agriculture University  
Hits: 2212
Download times: 786
中文摘要:
      为降低高压电缆金属护套感应电压,通常在电缆交叉互联箱内将高压电缆金属护套进行交叉互联。但是由于电缆铺设环境的复杂性,交叉互联箱会出现受潮、进水、外力破坏等诸多情形,导致高压电缆金属护套出现交叉互联故障,给整个系统的安全运行埋下隐患。文章针对110kV XLPE高压电缆的交叉互联故障进行分析,利用ATP—EMTP电磁暂态软件进行建模和仿真,分析总结出不同故障下的接地电流变化特点,为高压电缆的故障检测提供理论依据。
英文摘要:
      High voltage cable metal sheath is usually cross-bonded in the cable cross connection box in order to reduce the metal sheath voltage. Because of the complexity of the cable laying environment, cross connection box will appear damp, water, external damage or other situations, leading high voltage cable metal sheath cross fail in link box, buried the hidden trouble to the safe operation of the whole system. This paper analyzes the features of the ground current when the failure of cross-bond in 110kV XLPE high voltage cable occurs, then models and simulates by ATP-EMTP electromagnetic transient simulation software, providing a reference for the fault detection of high voltage cable.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd