• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
基于无线数据通信的智能变电站二次设备集成测试系统开发
Research on integrated testing technology of secondary equipment in smart substation based on wireless communication
Received:April 30, 2015  Revised:April 30, 2015
DOI:
中文关键词: 智能变电站  电磁暂态计算  无线通信  分布式终端
英文关键词: smart substation  electromagnetic transient calculation  wireless communication  distributed terminal
基金项目:
Author NameAffiliationE-mail
Luo Peng* State Grid Hebei Electric Power Research Institute luopeng1984@sohu.com 
Hao Xiaoguang State Grid Hebei Electric Power Research Institute yufeishine@sina.com 
Zhao Yuhao State Grid Hebei Electric Power Research Institute zhyh_sr2001@163.com 
He Lei State Grid Hebei Electric Power Research Institute 408294313@qq.com 
Hits: 2146
Download times: 698
中文摘要:
      针对现有的智能变电站仿真试验系统无法良好应用于变电站现场等问题,提出了一种基于无线数据通信的智能站二次设备集成测试方案,并研发了系统软硬件。该系统采用电磁暂态计算获取整站正常运行及间隔典型故障的电流电压值,通过专用的亚毫秒级高速同步无线数据通道将试验数据发送到各被测间隔,并开发分布式数据终端实现仿真测试系统与变电站二次系统的无缝连接,完成二次系统不同范围、不同功能的重点测试。通过实际变电站的模型搭建及故障仿真测试,验证了该测试系统的有效性。
英文摘要:
      According to the problem that the current smart substation simulation system can not be well applied in transformer substation, a novel integrated testing method is proposed for secondary equipment based on wireless data communication, and the hardware and software of testing system are developed also. In this system, electromagnetic transient calculation is adopted to get the current and voltage value of substation normal running or malfunction, which is transferred to the tested substation interval by special submillisecond wireless channel, and some distributed terminals are designed to realize the seamless connection between the simulation system and substation secondary system. This system can realize the integrated testing of different functions of secondary system in smart substation, and the effectiveness of the testing system is proved by substation model founding and fault simulation.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd