交/直流线路并行运行对铁心饱和不稳定的影响
Study on the impact of the AC / DC line running in parallel to the core saturation instability
Received:May 12, 2015  Revised:September 12, 2015
DOI:
中文关键词: 铁心饱和  谐波不稳定  直流偏磁  交直流线路并行架设。
英文关键词: core saturation  harmonic instability  DC bias  AC lines parallelly set up with DC lines.
基金项目:直流多馈入地区动态无功优化布局及系统谐波特性研究
Author NameAffiliationE-mail
(REN Yue* School of Electrical Engineering and Information,Sichuan University renyue1991@qq.com 
LIU Tianqi School of Electrical Engineering and Information,Sichuan University  
QIAO Guangyao State Grid Smart Grid Research Institute,Changping District  
YAN Xiaobin Southwest Electric Power Design Institute  
ZHOU Shengjun) State Grid Smart Grid Research Institute,Changping District  
Hits: 1782
Download times: 467
中文摘要:
      由于输电走廊紧张,存在交流输电线路与直流输电线路共走廊平行架设或者直接采用交直流线路同塔架设的情况,采用电磁暂态程序,建立了平行和同塔架设的高压交/直流线路电磁耦合模型及直流输电系统模型,计算了直流线路上工频感应电流以及交/直流侧的电压、电流畸变率,分析了并行交流线路对直流系统铁心饱和谐波不稳定的影响,并且研究了直流线路上工频感应电流的限制措施。
英文摘要:
      The corridor resource is very tight, the situation that HVDC lines and AC lines HVDC lines are parallelly erected with AC lines. Set up the electromagnetic coupling model of AC/DC lines which is parallel or same tower by the electromagnetic transient program. Calculate the fundamental frequency induction current of dc line and ac/dc side voltage and current distortion rate, analyzed the influence of parallel AC and DC line to core saturation instability, and studied the measure for limit the induced current on dc line.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd