文章摘要
光纤传感器在预装式变电站绕组热点温度监测中的应用
Application of fiber optic sensor in the hot spot temperature monitoring of the prefabricated substation windings
Received:June 27, 2015  Revised:June 27, 2015
DOI:
中文关键词: 光纤测温,预装式变电站,热点温度,在线监测,寿命评估
英文关键词: Fiber  optic sensor,prefabricated  substation,Hot  spot temperature,On-line  monitoring,Life  evaluation
基金项目:
Author NameAffiliationE-mail
Wang Jinfeng* Electric Power Research Institute of Guangdong Power Grid Co,Ltd,Guangzhou stare0405@163.com 
Xu Xiaogang Electric Power Research Institute of Guangdong Power Grid Co,Ltd,Guangzhou  
Li Xin Electric Power Research Institute of Guangdong Power Grid Co,Ltd,Guangzhou  
Hou Dan T & S Communications Co.,Ltd.  
Zheng Min T & S Communications Co., Ltd.  
Hits: 1520
Download times: 612
中文摘要:
      针对目前预装式变电站变压器室内部绕组热点温度在线监测困难的问题,本文提出了一种光纤传感应用方案,通过在变压器内布置光纤温度传感器进行在线监测,可以对变压器的热点温度进行监测,同时结合变压器负载情况对变压器的寿命损失评估。额定负载和过负载试验数据表明,该光纤在线监测系统能够准确、及时捕捉到变压器的热点温度,并给出过负载工况下的合理建议。
英文摘要:
      For the difficult problem of hot spot temperature on-line monitoring in prefabricated substation, this paper proposes an application of optical fiber sensing scheme, which fiber optic temperature sensors are installed in transformer. The effect of transformer load on the life loss of transformers is also evaluated in this paper. The data of rated load test and the overload test of transformer are indicated that the optical fiber on-line monitoring system can accurately and real-time capture the hot spot temperature of the transformer, and gives the reasonable suggestion of the load condition.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd