• HOME
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • Chinese
Site search        
文章摘要
配电网TV高压熔断器熔断影响因素的分析
The analysis on the influence factors of TV fuses blowing in the distribution network
Received:July 09, 2015  Revised:September 22, 2015
DOI:
中文关键词: 电压互感器,高压熔断器,铁磁谐振,防治措施,ATP-EMTP
英文关键词: voltage transformer, fuse, ferroresonance, prevention measures, ATP-EMTP
基金项目:
Author NameAffiliationE-mail
Zhao Mengya* School of Electrical and Electronic Engineering,North China Electric Power University jenny19901011@126.com 
Liang Zhirui School of Electrical and Electronic Engineering,North China Electric Power University  
Hits: 1347
Download times: 596
中文摘要:
      针对配电网时常发生的TV高压熔断器熔断的事故,分析了造成事故发生的主要原因为铁磁谐振和低频非线性振荡。本文利用ATP-EMTP建立仿真模型,对母线出线总长度、TV励磁特性、TV直流电阻和单相接地过渡电阻这4种TV高压熔断器熔断的主要影响因素进行仿真分析,得出了它们对TV高压侧过电流和系统谐振状态影响的一般规律。总结了现有的几种TV高压熔断器熔断的防治措施的优缺点,并对其消谐效果进行了仿真对比分析。
英文摘要:
      For frequent electromagnetic voltage transformer (TV) fuses blowing accident in the distribution network, This paper analyzes that the main cause of the accident are ferroresonance and low frequency nonlinear oscillation. It makes a simulation model by ATP-EMTP, and makes the simulation analysis on the four main influence factors of TV fuses blowing which are the total length of bus feeder line, TV excitation characteristic, TV Primary DC Resistance and the single-phase grounding resistance. It gets the general rules that these factors have influence on TV primary current and the resonance state. It summarizes the advantages and disadvantages of several existing prevention measures for TV fuses blowing, and compares of their harmonic elimination effect.
View Full Text   View/Add Comment  Download reader
Close
  • Home
  • About Journal
    • Historical evolution
    • Journal Honors
  • Editorial Board
    • Members of Committee
    • Director of the Committee
    • President and Editor in chief
  • Submission Guide
    • Instructions for Authors
    • Manuscript Processing Flow
    • Model Text
    • Procedures for Submission
  • Academic Influence
  • Open Access
  • Ethics&Policies
    • Publication Ethics Statement
    • Peer Review Process
    • Academic Misconduct Identification and Treatment
    • Advertising and Marketing
    • Correction and Retraction
    • Conflict of Interest
    • Authorship & Copyright
  • Contact Us
  • 中文页面
Address: No.2000, Chuangxin Road, Songbei District, Harbin, China    Zip code: 150028
E-mail: dcyb@vip.163.com    Telephone: 0451-86611021
© 2012 Electrical Measurement & Instrumentation
黑ICP备11006624号-1
Support:Beijing Qinyun Technology Development Co., Ltd